Operating Voltage 12~24 VDC (auto sensing)
The ENFORCER SA-025MQ Multi-Function Programmable
Timer saves time with 7 programmable modes for a variety
of common situations. Settings are easily programmed using
three pushbuttons and an LED display.
12~24VDC (auto-sensing) operation
Low current draw
7 modes easily programmable with pushbuttons and LED
display (auto door or gate closure, guard timer, pulse extender /
false trigger avoidance, timed relay output, timed pulse relay
output, input counter, input timer)
Timer can be set to trigger a notification (red LED and/or
buzzer) and/or a Form C relay output (10A@24VDC)
Timer can be set from 1sec~11h 59min
Can be triggered by N.O. pos. (+) or N.C. neg. (–) input, or by
powering up the unit
Relay can be programmed to trigger at the start or end of the
timing cycle, or to toggle
Relay can be programmed to pulse (0.5sec on / 0.5sec off) or
steady on (1sec~11h 59min)
Includes reset input (N.O.–) to manually reset cycle